  click here new adam-6066 6-ch digital input and 6-ch power relay modbus tcp module main features ? 6-ch di, 6-ch rl, ethernet-based smart i/o ? remote monitoring and control with mobile devices ? group confguration capability for multiple module setup ? flexible user-defned modbus address ? intelligent control ability by peer-to-peer and gcl function ? active i/o message by data stream or event trigger function ? multiple protocol support: modbus tcp, tcp/ip, udp, http, dhcp ? web language support: xml, html 5, java script introduction adam-6000 accomplishes the integration of automation and enterprise systems easily through internet technology, so that users can avoid changing the entire architecture of the control system and even remotely monitor the device status more fexibly. adam-6000 modules are empowered by peer-to-peer (p2p) and graphic condition logic (gcl), and can perform as standalone products for measurement, control and automation. instead of having additional controllers or programming, system confgurations can be done in an extremely short time with the easy-to-use and intuitive graphic utility. features group confguration capability for multiple module setup to aid confguration and save time, engineers can confgure and upgrade the frmware of multiple adam-6000s simultaneously. architecture remote monitoring and control with smart phone with support for html5, the adam-6000 can be monitored and controlled from any browser on mobile devices whilst in the feld and when the engineer is connected to their network. advanced security and high reliability adam-6000 ethernet i/o modules have fast response time, and advanced security and reliability. when communication is broken, the digital output module can generate pre- defned values to ensure safety. peer-to-peer modules will actively update the input channel status to specifc output channels. without dealing with the trouble of long distance wiring, users can defne the mapping between a pair of modules. graphic condition logic users can defne the control logic rules through graphical confguration utility, and download defned logic rules to specifc adam module. then, it will execute the logic rules automatically just like a standalone controller. last updated : 10-jun-2014 ethernet i/o modules more information all product specifications are subject to change without notice
adam-6066 remote i/o specifcations digital input ? channels 6 ? dry contact logic level 0: close to gnd logic level 1: open ? wet contact logic level 0: 3 v dc logic level 1: 10 ~ 30 v dc ? supports 3 khz counter input (32-bit + 1-bit overfow) ? keep/discard counter value when power-off ? supports 3 khz frequency input ? supports inverted di status relay output (form a) ? channels 6 ? contact rating 250 v ac @ 5 a, 30 v dc @ 3 a (resistive) ? breakdown voltage 500 v ac (50/60 hz) ? relay on time 7 ms ? relay off time 3 ms ? total switching time 10 ms ? insulation resistance 1 g ? min. at 500 v dc ? maximum switching 20 operations/minute rate (at rated load) ? supports pulse output general ? lan 10/100base-t(x) ? power consumption 2.5 w @ 24 v dc ? connectors rj-45 (ethernet), plug-in screw terminal block (i/o and power) ? watchdog system (1.6 second) and communication (programmable) ? power input 10 ~ 30 v dc ? dimensions (w x h x d) 70 x 122 x 27 mm ? enclosure pc ? mounting din 35 rail, stack, wall ? supports peer-to-peer, gcl ? supports user defned modbus address ? supports modbus/tcp, tcp/ip, udp, dhcp and http protocols protection ? power reversal protection ? isolation protection 2,000 v dc environment ? operating temperature -20 ~ 70c (-4 ~ 158f) ? storage temperature -30 ~ 80c (-22 ~ 176f) ? operating humidity 20 ~ 95% rh (non-condensing) ? storage humidity 0 ~ 95% rh (non-condensing) software ? .net class library (sdk) windows and windows ce class library, vb and vc# sample code for i/o reading or confguration and communication ? adam/apax .net utility network setting, i/o confguration, data stream, p2p, gcl confguration pin assignment ordering information ? adam-6066 6-ch di and 6-ch power relay modbus tcp module accessories ? pwr-242 din-rail power supply (2.1a output current) ? pwr-243 panel mount power supply (3a output current) ? pwr-244 panel mount power supply (4.2a output current) software ? pcls-adamview32 adamview data acquisition software ? pcls-opc/mtp30 opc server for modbus/tcp protocol unit: mm dimensions www.advantech.com/products online download


▲Up To Search▲   

 
Price & Availability of ADAM-6066-14

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X